What size air conditioner does your room need?

Enter the size of the room and what it’s like. We’ll tell you what capacity to look for (in BTU and kW) and how much electricity the unit will use.

Floor length × width. For example, 4 × 4 metres = 16 m², or 12 × 14 feet = 168 sq ft.

From the third person on, each one adds 600 BTU.

To see how much it will use

Check your bill: the total divided by the kWh.

🔒 The maths runs on your own phone or computer. We don’t store or send your data.

The capacity you need

—
In kW of cooling
—
not what it uses
In frigories
—
per hour (used in Argentina)

Look for a unit with this capacity or the nearest one above it. A much bigger one isn’t better: according to ENERGY STAR, it cools the room before it can remove the humidity, leaving it cold but clammy, and it wastes energy.

    What it will use

    Draws from the grid
    —
    at full power
    Per day
    —
    Per month
    —

    How it’s worked out

    1. The base capacity comes from the ENERGY STAR table (the U.S. government’s efficiency program), which goes by floor area in square feet. The calculator also accepts square metres (1 m² = 10.76 sq ft).
    2. It’s then adjusted the way ENERGY STAR says: 10% less if the room is heavily shaded, 10% more if it’s very sunny, 600 BTU more for each person from the third one who’s usually in the room, and 4,000 BTU more if it’s a kitchen. The 10% applies to the table figure; people and kitchen are added after.
    3. kW and frigories. 1 kWh is 3,412 BTU (EIA), and 1 frigorie per hour (the unit used in Argentina and Uruguay) is about 3.968 BTU per hour. These figures say how much the unit cools, not how much electricity it uses.
    4. What it uses = BTU ÷ the unit’s efficiency (its EER or CEER, which is exactly that: BTU of cooling per watt of electricity). It’s the same sum the U.S. Department of Energy’s buying guidance uses: a 12,000 BTU unit with a CEER of 14.7 running 750 hours uses 12,000 × 750 ÷ 14.7 = 612 kWh a year.
    5. Per day = watts × hours × 0.75. With the thermostat, the compressor isn’t flat out all the time: in the official table of Argentina’s energy regulator (ENRE), a 1,350 W air conditioner of 2,200 frigories uses 75% of its power in an hour.

    The ENERGY STAR table

    Area (sq ft)Area (m²)BTU per hour
    100 to 1509.3 to 13.95,000
    150 to 25013.9 to 23.26,000
    250 to 30023.2 to 27.97,000
    300 to 35027.9 to 32.58,000
    350 to 40032.5 to 37.29,000
    400 to 45037.2 to 41.810,000
    450 to 55041.8 to 51.112,000
    550 to 70051.1 to 6514,000
    700 to 1,00065 to 92.918,000
    1,000 to 1,20092.9 to 111.521,000
    1,200 to 1,400111.5 to 130.123,000
    1,400 to 1,500130.1 to 139.424,000
    1,500 to 2,000139.4 to 185.830,000
    2,000 to 2,500185.8 to 232.334,000

    ENERGY STAR works these capacities out for an 8-foot (2.4 m) ceiling. If yours is higher, it advises a more powerful unit but doesn’t say how much: in that case, have an installer work it out.

    An example

    A 4 × 4 metre bedroom (16 m², which is 172 sq ft), very sunny, where 3 people sleep:

    • From the table, 150 to 250 sq ft: 6,000 BTU.
    • Very sunny: 6,000 × 10% = 600 BTU more → 6,600.
    • The third person: 600 BTU more → 7,200 BTU per hour, which is 7,200 ÷ 3,412 = 2.11 kW of cooling (or 1,815 frigories).
    • With a new unit at the U.S. minimum (CEER 10.9): 7,200 ÷ 10.9 = 661 W. On for 8 hours: 661 × 8 × 0.75 = 3.96 kWh a day, about 119 kWh a month.
    • With an ENERGY STAR certified one (CEER 14.7): 7,200 ÷ 14.7 = 490 W, about 88 kWh a month.

    Efficiency: EER, CEER and W/W

    All three measure the same thing: how much cooling the unit gives for each watt of electricity it uses. The higher, the less it uses to cool the same.

    • In the U.S. and much of the Americas it’s given in BTU per watt-hour (for example 10.9 or 14.7).
    • In Europe and the UK it’s given in W/W (kW of cooling over kW of electricity, for example 3.2). To convert it to BTU/Wh, multiply by 3.412.
    • In the U.S., a window unit of 8,000 to 13,999 BTU must have a CEER of at least 10.9 to be sold, and 14.7 to carry the ENERGY STAR label (Department of Energy FEMP guidance, updated December 2024). The old non-inverter units in Argentina’s ENRE table work out at about 6.5.

    To make it use less

    • Set the thermostat as high as is comfortable; ENERGY STAR suggests about 78 °F (26 °C).
    • On humid days, set the unit’s fan to low: slower air removes more moisture from the room.
    • Don’t put lamps or TVs near the unit’s thermostat: their heat makes it run longer.
    • A fan helps spread the cool air around the room.
    • Make sure it’s well sealed in the window: according to ENERGY STAR, a badly installed one leaks as much air as a 6-square-inch hole.

    A window or wall air conditioner is plugged straight into the wall, never into a power strip or extension cord. Split systems and large units go on their own circuit: they must be installed by an installer or electrician, who can also fine-tune the capacity for your home.